Skip to end of banner
Go to start of banner

W-PA SIP Paging Gateway Manual - English

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 12 Next »

This guide explains how to install and use W-PA SIP Paging Gateway and provides a description of its basic functions.

Created: December 2017

Permalink: https://confluence.wildix.com/x/BQAVAQ


W-PA SIP Paging Gateway Introduction

W-PA SIP Paging Gateway is a Public Announcer used to broadcast emergency messages and communication in large environments. The device has 10 watt audio output and it still allows you to connect external loudspeakers, and an external microphone. It can also act as a relay for activating door release switches or door locks via 1 embedded short-in detect port and 1 short-out control port (See Appendix 1 for more information).

Before using W-PA SIP Paging Gateway

Please read the following safety notices before installing or using this W-PA. They are crucial for the safe and reliable operation of the device:

  • Before using the device, make sure that the environment temperature and humidity requirements are within these ranges: 
    • Operating temperature: -30 ~ 70 ℃ 
    • Storage temperature: -40 ~ 70 ℃ 
    • Relative humidity: 10% - 95%
  • Do not put any foreign objects into the ports of the device. It may cause electric shock or injury accident. If any foreign object gets inside the device, please stop using it
  • Do not let non-technical staff to remove or repair the device. Consider that improper repair may lead to injury accident or cause damage of the device

Packing list 

Before you start to install W-PA, please verify that your package contains the following items:

  • 1 x W-PA SIP Paging Gateway
  • 1 x ground screw

W-PA Overview

Front panel

1 - PC port: connect the device to PC (optional)

2 - WAN (PoE) port: standard RJ45 interface, 10/ 100M adaptive, it is recommended to use five or super five network cable to connect the device to the network

Note: W-PA is also powered by the network cable; the power adapter is optional.

3 - Registration/ Network LED: indicates registration, network and call statutes

  • fast blue blinking: network anomaly or SIP account exception
  • slow blue blinking: during a call
  • solid blue: successful registration

4 - Volume - button

5 - Volume + button

6 - Reset button

7 - Speaker 3 output interface: connect external speaker or MIC 

8 - Ground screw: connect external parts with metal housing to this interface to prevent static electricity and other interference caused the equipment to work abnormally

Rear panel

1 - Speaker 1 interface: according to the device input voltage, adaptive output maximum power is 30W; 4Ω speaker

2 - Speaker 2 interface: connect external headsets or active speakers

3 - LED interface: 5V output, connect an external LED, indicating the network, call and registration statuses

4 - Switch input 2 interface: connect switch components to this interface

5 - MIC interface: it is recommended to use an electret condenser microphone and connect it with a shielded cable to the grounding screw to improve anti-interference

6 - Switch input 2 interface: connect switch components to this interface

7 - Switch output interface: corresponds to the short-circuit (switch input 2)  input interface

8 - 12V ~ 24V 2A input, according to the input voltage, determine the maximum W-PA output power 

Instalation of W-PA SIP Paging Gateway

Connecting W-PA 

  • Use five or super five network cable to connect your W-PA to the network
  • Connect the cable to WAN (PoE) port

W-PA Web Configuration

  1. Access W-PA web interface for configuration settings:
    • Press Volume - button for 3 seconds to obtain its IP address
    • IP address will be playbacked through the speaker
    • First time access credentials: admin : admin
  2. After you log in W-PA web interface, go to System -> Auto Provision -> Static Provisioning Server and fill in the following information:
    • Server Address: enter your PBX address (maartentest.wildixin.com:443 in the example)
    • Configuration File Name: ?action=setaps
    • Protocol Type: HTTPS
    • Update Interval: Set the interval of update in case you choose Update at Time Interval update mode in the next step
    • Update Mode: Select the update period: Update After Reboot / Update at Time Interval
  3. Click Apply

Reboot 

The next step is to reboot your W-PA:

  1. Go to System -> Tools -> Reboot phone
  2. Click Reboot button
  3. Confirm the reboot by clicking OK
  4. You will hear two audio signals: the first one is played at the beginning of the reboot, the second one is played after it is completed

Provisioning 

Auto-provisioning

W-PA SIP Paging Gateway can be auto-provisioned in case it is connected to the local LAN or remote network via VPN.

Please refer to the Provisioning of Wildix devices Guide for detailed information.

Semi-automatic provisioning

Semi-automatic provisioning is used for remote/unreachable devices behind NAT/Firewall:

  1. Go to WMS -> Devices
  2. Click Add
  3. Enter MAC address of the device (you can find it on the device label or check it in W-PA web interface -> System -> Information -> Network -> MAC)
  4. Click Next. You will be forwarded to the provisioning window with the device information (MAC, Type and Provisioning URL)
  5. Click Finish

Note: in case you can see the model type, login1, the firmware version and the password of the device in WMS -> Devices, it means that it is provisioned.


Assign to user

To assign a user to your W-PA SIP Paging Gateway:

  1. Go to WMS -> Devices 
  2. Choose your W-PA from the list of available devices and click Assign to user
  3. Enter the extension number of a user you want to assign the device to

    Note: you can use the existing extension number or create a new one.

Public announcer function

Once your W-PA SIP Paging Gateway is installed and configured, you can use it as a Public Announcer for broadcasting purposes.

Note: to use your W-PA SIP Paging Gateway as a Public Announcer, you may need to connect external loudspeakers via SPK interfaces.

To broadcast a message via W-PA:

  1. Call the extension number you've assigned the device to from any Wildix IP phone/ Collaboration/ Mobile app

  2. The device will auto answer and play back your voice over SPK1 and/ or SPK2

  3. If you want to finish broadcasting, click Hangup (red) icon to hang up a call

Factory reset

In case you need to reconfigure your W-PA, you should perform a reset procedure.

To restart and restore the factory settings of W-PA SIP Paging Gateway:

Press and hold for 3 seconds the Reset button

  • No labels