In this Admin Guide you can find provisioning variables
Updated: March 2018
Permalink: https://confluence.wildix.com/x/KQg8AQ
When provisioning Wildix devices, you can set custom parameters to change different settings in the provisioning file.
All the changes must done in the file /rw2/etc/provision.conf (ini syntax - http://en.wikipedia.org/wiki/INI_file).
Access the file via SSH as root using the command:
nano-tiny /rw2/etc/provision.conf
The parameters can be set for a specified device by adding them to one of these sections:
- [wildixp] - WP
- [wildixp2] - WP480R2
- [wildixfxo] - W04FXO
- [wildixgw] - Media Gateways
- [wildixair] - W-AIR
Otherwise, you can apply the parameters to all the registered devices by adding them to [general] section.
List of supported parameters:
Parameters | Values | Description |
---|---|---|
SIPServerPort | =0-65535 | set SIP Server Port of the device registered to the account |
SIPServerPortRemote | =0-65535 | set SIP Server Port of the device of the registered account in the device behind NAT |
SIPTransport | =UDP|TCP|TLS | set SIP transport protocol of the device registered to the account |
SIPTransportRemote | =UDP|TCP|TLS | set SIP transport protocol of the registered account in the device, located behind NAT |
HTTPForceUse | =yes|no | disable/ enable force HTTP protocol instead HTTPS for all requests from the device, like provision, phonebook, features, etc. Supported only by after the parameter is set, a device should be re-provisioned. Supported only by WP and WP480R2) |
RawScan | =enable|disable | only for [general] section. Disable/ enable raw scanning method in case of automatic provision (useful feature for PBX inside chroot environment) |
BLFTransType | =attended|blind | only for [wildixp] section. Set BLF transfer type. Supported only by WP480, WP490 and WPp600 |
RequireAuth | =yes|no | only for [general] section. Enable/ disable making provision authorization for local devices |
TrustLocalDevice | =yes|no | only for [general] section. Enable/ disable an automatic adding local device to provision database (Note: for W-AIR you have create network manually via WMS interface) |
POWER_LED | =yes|no | only for [wildixp2] section. Enable/ disable WP 2015 Power LED ("no" - disable, "yes" - enable) |
PowerLEDBlinkTime | =0-14400 | only for [wildixp2] section. Set the time in seconds during which the LED of a missed event (call or voice mail) will blink. If "0" - blink always, if "1" - blink only once |
HIDE_DTMF | =yes|no | hide/ show DTMF visualisation on displays of phones ("no" - show, "yes" - hide) |
XMLBrowserAuth | =yes|no | enable/ disable the pin-protection for the voicemail-menu. Important: removed in rev 39338. Clients must use "can use"/"cannot use" "Voicemail without pin code" ACL instead. |
g711only | =yes|no | only for [wildixair] section. Set only g711 codecs ("yes" - enable, "no" - disable). The parameter is applied only to W-AIR Bases |
ResetHandset | =yes|no | only for [wildixair] section. The parameter is disabled by default. In case you need to delete a Handset IPEI from W-AIR SB and to reuse the slot, set to "yes" in case if you need to delete an handset IPEI from W-AIR SB sb and allow to reuse the slot. After slot is cleared, you need to disable this parameter |
DisableCodecG729 | =yes|no | only for [wildixair] section. Disable g729 codecs ("yes" - disable, "no" - enable). The parameter is applied only to W-AIR Small Business Bases |
LossPktRateMin | =0-100 | set the parameter to control Packet Loss. Network Problem Threshold 1-99, "100" - disable. Supported only by WP4x0. After the parameter is applied, the device should be re-provisioned. |
LossPktRateMax | =0-100 | set the parameter to control Packet Loss. Critical Network Problem Threshold 1-99, "100" - disable. Supported only by WP4x0. After the parameter is applied, the device should be re-provisioned. |
BLFNotifyType | =ActiveCall|ActiveAndIncomingCall | only for [wildixp2] section. The parameter is set to "ActiveCall" by default. BLF will blinks in case when monitored user has active call+incoming call if "ActiveAndIncomingCall" or keep the old behavior if "ActiveCall" |
FailoverPbxIp | =<IP address> | only for [wildixp2] section. Force the switch from Main PBX to Failover PBX (SIP Server 2). Use only IP address |
Limitations:
You have to add empty section for loading parameters from [general] section.
For example you added parameter HTTPForceUse = yes to general section. You have to add empty section wildixp2 if you want to apply this parameter for WPR2 devices.
WP2015 does not apply the parameter POWER_LED and PowerLEDBlinkTime without rebooting the device.