The following Admin Guide describes Trunk Settings and explains how to set up various parameters.

Updated: September 2021

WMS version: WMS 5.0X / WMS 4.0X

Permalink: https://confluence.wildix.com/x/8Qk8AQ


Table of Contents

Introduction

...

Check out Wildix supported VoIP providers in the USA, Italy, Germany, France, Switzerland, the Netherlands, Austria, Spain, the UK and examples of configuration on THIS PAGE.

Supported custom config parameters

...

  • Pricelist: the pricelist to calculate the costs for calls through the trunk
  • Local Area Code: specify the area code
  • Dialplan: Dialplan procedure for routing calls coming from this trunk (usually, “main”)
  • Hotline Number: the number corresponding to the line which is present in the associated Dialplan procedure
  • Detect caller ID (available for FXO gateways pre 2020): enable/disable caller ID detection
  • Caller ID type (available for FXO gateways pre 2020): select the standard for transmitting the caller ID information
  • Flash time (available for FXO gateways pre 2020): timeout (in msec) for hookflash detection
  • Dialing answer delay time: interdigit dial timeout (in sec), when terminated, the call is sent to trunk (the value cannot be less than “1”)
  • FAX type: select the mode (T38 or Bypass)
  • Gain RX FXO: adjust incoming audio gain
  • Gain TX FXO: adjust outgoing audio gain
  • Disconnect signaling (the parameter is available for W04FXO R3 starting from WMS 5.03):
    • Busy tone (the default value)
    • Polarity reversal: enable/ disable this parameter to avoid dropped calls due to a wrong detection of polarity change on the copper line
    • Open switching interval: enable/disable the parameter and set the Current Disconnect Threshold in ms
  • Polarity reversal on answer: enable/ disable this parameter as the cause for disconnecting the call
  • Silence detection: enable/ disable this parameter as the cause for disconnecting the call and specify the timeout in seconds

...